Home
Projects
Products
About Us
Field Service, Engineering, & Inspections
Request a Quote
Metal Expansion Joints
Fabric Expansion Joints
Rubber Expansion Joints
Dampers
Corrosion Engineering
Contact Us
Associations
Need Representation?
Home
Projects
Products
About Us
Field Service, Engineering, & Inspections
Request a Quote
Metal Expansion Joints
Fabric Expansion Joints
Rubber Expansion Joints
Dampers
Corrosion Engineering
Contact Us
Associations
Need Representation?
Author: IFTTT
We know you want to do your job right the first time so you can leave for the woods and have peace of mind while you’re away. INTEREP is here to help make that happen. Call us and we’ll do the detail work for you.
Posted
by
IFTTT
on Oct 29, 2019
in
Projects
|
No Comments
Read More
These Proco Products Penetration Seals were just installed in the chemical & sludge wet wells at a combined cycle power plant. They can be unchained, wrapped around the pipe, slid into place, and then expanded to create a watertight seal. Excellent for retrofit applications.
Posted
by
IFTTT
on Aug 16, 2019
in
Projects
|
No Comments
Read More
A Robinson Fan ready to ship to one of our local customers. Robinson can design, re-engineer, manufacture and field-service your fan.
Posted
by
IFTTT
on Jun 7, 2019
in
Projects
|
No Comments
Read More
You know yesterday’s day shift took longer than you thought it would when you see the sun begin to rise while you’re finishing up an emergency penetration seal repair.
Posted
by
IFTTT
on Jun 5, 2019
in
Projects
|
No Comments
Read More
We ran into a welder with our sticker on his hood while doing some HRSG penetration seal repairs this weekend. He’s had it on there since 2003 when we showed him how to splice Teflon expansion joints on air ducts at a different power plant!
Posted
by
IFTTT
on Jun 1, 2019
in
Projects
|
No Comments
Read More
Pennguard Block being installed on top of Pennguard Adhesive Membrane by International Chimney with supervision by Hadek.
Posted
by
IFTTT
on May 29, 2019
in
Projects
|
No Comments
Read More
We were disappointed to see that this rubber expansion joint was missing proper limit rod hardware.
Posted
by
IFTTT
on Apr 30, 2019
in
Projects
|
No Comments
Read More
The inside of a pre-calciner (preheater) tower at a cement plant. In this system the hot combustion gasses from the kiln are passed up through the falling raw meal in a series of cyclones. The average preheater typically produces a hot feed that is 20% calcined when it enters the kiln, increasing the clinker output of the plant. Watch out for stainless steel that exhibits signs of chloride stress corrosion cracking on your preheater tower. Salts in the raw mix are often evaporated in the kiln and re-condense on cool points further upstream in the form of sodium chloride or potassium chloride.
Posted
by
IFTTT
on Apr 12, 2019
in
Projects
|
No Comments
Read More
Last load of Pennguard Block that International Chimney is installing in a 700’ stack. The Pennguard Block lining system provides an impervious barrier for the inside of chimney flues, protecting them from acidic condensation. It is also an excellent insulator, which helps keep the temperature of your wet-scrubbed flue gas higher – reducing steam plume and liquid carryover.
Posted
by
IFTTT
on Apr 8, 2019
in
Projects
|
No Comments
Read More
We got a call complaining that the new brick floor we supplied to this acid plant was heaving and cracking it’s phenolic mortar joints. We discovered that although the phenolic mortar could take hot sulfuric acid, as could the brick, there was a Viton (flouroelastomer) expansion joint right beneath the hot acid tank in this picture. Whenever the tank overflowed it destroyed the expansion joint – exposing the asphaltic membrane beneath to hot H2SO4, which caused membrane failure and allowed sulfuric acid into the concrete foundation. Call Interep for tips on your brick design to avoid situations like this.
Posted
by
IFTTT
on Mar 20, 2019
in
Projects
|
No Comments
Read More
Recon Engineering & Construction has been having fun blasting out refractory cement from the inside of the preheater tower at this cement plant. Once it’s all cleaned out they’ll do steel repairs, weld in anchors where the old ones have failed (our S-Bar anchors can help with that issue) and then shoot new refractory cement. This is the best time to replace refractory-lined expansion joints because the refractory contractor can line the expansion joint at the same time as the ductwork, saving the plant money.
Posted
by
IFTTT
on Mar 19, 2019
in
Projects
|
No Comments
Read More
A combination of pipe stress due to poor anchoring & sulfuric acid buildup from SO2 rich gas caused the flanges on this composite expansion joint belt to separate from the duct. If this happens on a positive pressure duct you introduce unintended & unmonitored emissions. If the duct is negative pressure you’re bringing ambient (cold) air into your process (which is already full of SO2 – speeding formation of sulfuric acid H2S04) and increasing parasitic load on your fans.
Posted
by
IFTTT
on Mar 7, 2019
in
Projects
|
No Comments
Read More
The rectangular metal bellows on this feed shelf was exposed to 1600F temperatures and deformed. The duct is lined with high-temperature refractory and the expansion joint is packed with ceramic insulation. The air cannons here blew the refractory off of the walls near the expansion joint and so it was no longer protected from the high gas temperatures.
Posted
by
IFTTT
on Mar 5, 2019
in
Projects
|
No Comments
Read More
This Proco customer figured they could use ductile iron flanges on their 443-BD expansion joint because the 78% sulfuric acid wouldn’t get on the outside of the process piping. After 3 years, turns out the best case scenario wasn’t real life. They’ve since switched to using 316 stainless flanges.
Posted
by
IFTTT
on Mar 1, 2019
in
Projects
|
No Comments
Read More
A crude heater at an oil refinery where the original Carl Horecky was called in as a consultant with Horecky / Fahrig Associates to revamp the catcracker with his high temperature regeneration technology. Looks like these heavy-wall expansion joints might have seen more angular movement than they were designed for.
Posted
by
IFTTT
on Feb 23, 2019
in
Projects
|
No Comments
Read More
If your vent silencer is causing lots of noise on startup it could have damage from internal corrosion. Interep & SVI Dynamics can inspect, diagnose, re-engineer, and repair it for you.
Posted
by
IFTTT
on Feb 20, 2019
in
Projects
|
No Comments
Read More